Home>>FAQ>>Mains Lost

Mains Lost

Fault Reasons:Inverter will show “Mains Lost” when the AC grid disconnected.

Troubleshooting:
1. Check if the mains(power grid) is working normal, please enter the next step if it is;

2. Check if the AC breaker or other protection switches are turned off, please enter the next step if it isn’t;

3. Check the L, N and PE cables which are connected in the inverter AC terminal are in the same sequence with the marks on it;

4. Use a multimeter to measure whether the voltage between L and N wire of the mains(power grid) at the inverter output terminal is around 230V, the mains is abnormal if it isn’t;

5. Check if the AC breaker, knife-switch, overvoltage protector or other safety protectors are working properly;

6. Please contact sunways after-sales team at service@sunways-tech.com or +86 400 9922 958 if all steps above have been checked and excluded.

2020-10-27T11:12:14+00:00

Go to Top